| Multi-Function Meters & Transducers | Active & Reactive Power | Current | Voltage | Frequency | Phase Angle | Power & CurrentTransducers |
|---|
| Power Transducers | ||||
|---|---|---|---|---|
| Sineax P 530 Active Power & Q 531 Reactive Power Transducers | ||||
| Input: | 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 100-690 V 50/60 Hz |
Output: | 0-1 mA to 0-20mA 1-5 mA to 4-20 mA ±1 mA to ±20 mA 0-1 V to 2-10 V, to ±10 V |
![]() |
Instructions, 3-Phase Models Instructions, Single Phase Models |
||||
| Current Transducers | ||||
| Sineax I 538 AC Current Transducer | ||||
| Input: | 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 50/60 Hz |
Output: | 0-20 mA, 4-20 mA 0-1 V to 0-10 V, 2-10 V |
|
Instructions |
||||
| Sineax I 542 AC Current Transmitter | ||||
| Input: | 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 50/60 Hz |
Output: | 0-20 mA 0-1 V to 0-10 V, 2-10 V |
|
Instructions |
||||
| Sineax I 552 True RMS AC Current Transducer | ||||
| Input: | 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 50/60 or 400 Hz |
Output: | 0-20 mA, 4-20 mA 0-1 V to 0-10 V, 2-10 V |
![]() |
Instructions |
||||
| Voltage Transducers | ||||
| Sineax U 539 AC Voltage Transducer | ||||
| Input: | 0-50 V to 0-600 V 50/60 Hz |
Output: | 0-1 mA to 0-20mA 1-5 mA to 4-20 mA 0-1 V to 2-10 V |
|
Instructions |
||||
| Sineax U 543 AC Voltage Transducer | ||||
| Input: | 0-20 V to 0-600 V 50/60 Hz |
Output: | 0-1 mA to 0-20mA 0-1 V to 0-10 V |
|
Instructions |
||||
| Sineax U 553 True RMS AC Voltage Transducer | ||||
| Input: | 0-20 V to 0-690 V 50/60 or 400 Hz |
Output: | 0-1 mA to 0-20mA 1-5 mA to 4-20 mA 0-1 V to 2-10 V |
|
Instructions |
||||
| Sineax U 554 True RMS AC Voltage Transducer | ||||
| Input: | 0-20 V to 0-690 V 50/60 or 400 Hz |
Output: | 0-1 mA to 0-20mA 1-5 mA to 4-20 mA 0-1 V to 2-10 V |
|
Instructions |
||||
| Frequency Transducers | ||||
| Sineax F 534 Frequency Transducer | ||||
| Input: | 10 V to 690 V 10 to 1500 Hz |
Output: | 0-1 mA to 0-20mA 1-5 mA to 4-20 mA ±1 mA to ±20 mA 0-1 V to 2-10 V, to ±10 V |
![]() |
Instructions |
||||
| Sineax F 535 Frequency Difference Transducer | ||||
| Input: | 10 V to 690 V 10 to 1500 Hz |
Output: | 0-1 mA to 0-20mA 1-5 mA to 4-20 mA ±1 mA to ±20 mA 0-1 V to 2-10 V, to ±10 V |
|
Instructions |
||||
| Phase Angle (Power Factor) Transducers | ||||
| Sineax G 536 Phase Angle Transducer | ||||
| Input: | 1 or 5 A 10 V to 690 V 16 to 400 Hz 0.5 cap. 1.ind. 0.5 cos Φ |
Output: | 0-1 mA to 0-20mA 1-5 mA to 4-20 mA ±1 mA to ±20 mA 0-1 V to 2-10 V, to ±10 V |
|
Instructions |
||||
| Sineax G 537 Phase Angle Difference Transducer | ||||
| Input: | 10 V to 690 V 50 or 60 Hz |
Output: | 0-1 mA to 0-20mA 1-5 mA to 4-20 mA ±1 mA to ±20 mA 0-1 V to 2-10 V, to ±10 V |
|
|
||||
| Power & Current Transducers | ||||
| Sineax M 561 Power & Current Transducer | ||||
| Input: | 0-1 A to 0-6 A 57-400 V phase-to-neutral 100-693 V phase-to-phase 50 or 60 Hz |
Output: | One Analog Output 0-20 mA, 4-20 mA 0-1 V to 0-10 V 2-10 V |
|
Instructions Software for M560 series |
||||
| Sineax M 562 Power & Current Transducer | ||||
| Input: | 0-1 A to 0-6 A 57-400 V phase-to-neutral 100-693 V phase-to-phase 50 or 60 Hz |
Output: | 2 Analog Outputs 0-20 mA, 4-20 mA 0-1 V to 0-10 V 2-10 V |
|
Instructions Software for M560 series |
||||
| Sineax M 563 Power & Current Transducer | ||||
| Input: | 0-1 A to 0-6 A 57-400 V phase-to-neutral 100-693 V phase-to-phase 50 or 60 Hz |
Output: | 3 Analog Outputs 0-20 mA, 4-20 mA 0-1 V to 0-10 V 2-10 V |
|
Instructions Software for M560 series |
||||
| Phone: 800-942-0315 or 847-918-3510 | Fax: 800-949-7502 or 847-968-4891 | |