Power Transducers Multi-Function Meters Multi-Function Transducers LONWORKS MODBUS PROFIBUS Power & CurrentTransducers
Multi-Function Power Meters
Sineax A210 & A220 Multifunction Power Meters
Input: Single or 3-phase
0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
Output: Digital pulse
Relay
A210 and A220

CE logoemmodEMMOD
  • A210 1/4 DIN size or A220 full-Size DIN
  • 19 types of measurements including
  • P, Q, S, I~, U~ (rms), cos φ, (PF, 4 quadrants), f, Pint, Qint, Sint
  • 3 variable display
  • Open collector alarm relay and pulse outputs
  • Data logging, RS232, and MODBUS with EMMOD 201 option
  • Two analog outputs with EMMOD 202 option
  • Ethernet interface with EMMOD 203 option
  • PROFIBUS interface with EMMOD 204 option
  • Hi/Lo electrical rates
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
A210/A220 Specifications
A210/A220 Instructions
EMMOD201>> A200Plus Software
EMMOD201 MODBUS
EMMOD202 Analog Outputs
EMMOD203
EMMOD203 Ethernet
EMMOD204
EMMOD204 PROFIBUS GSD File
Sineax A230 & A230s Multifunction Power Meter w. System Load & Harmonics
Input: Single or 3-phase
0-1 A to 0-6 A
290 V phase-to-neutral
500 V phase-to-phase
50/60 Hz
Output: Digital pulse
Relay
A230 and A230s

CE logoemmod EMMOD


Top of page
  • A230 full-Size DIN or A230s 1/4 DIN
  • 19 Types of measurements including
  • P, Q, S, I~, U~ (rms), cos φ (PF, 4 quadrants), f, Pint, Qint, Sint, THD, harmonics, UNE, unbU
  • Three 4-digit programmable displays
  • Open collector alarm relay and pulse outputs
  • Data logging, RS-232, and MODBUS with optional EMMOD 201
  • Two analog outputs with EMMOD 202 option
  • Ethernet interface with EMMOD 203 option
  • PROFIBUS interface with EMMOD 204 option
  • Hi/Lo electrical rates
  • Comprehensive mean and max./min. value functions with trend
  • System analysis functions (THD, harmonics, asymmetry)
  • Higher accuracy
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
Brochure
A230/A23s Specifications
A230/A230s Instructions
EMMOD201>> A200Plus Software
EMMOD201 MODBUS
EMMOD202 Analog Output
EMMOD203
EMMOD203 Ethernet
EMMOD204
EMMOD204 PROFIBUS GSD File
Sineax A-Plus True RMS Multifunction Power Meter with Power Quality Analysis
Input: Single or 3-phase
0-1A to 0-6 A
400 V phase-to-neutral
690 V phase-to-phase
50/60 Hz
1 digital input
Output:

Programmable
1 digital pulse
1 relay
Modbus

A Plus

Top of page
  • Power quality analysis
  • Display 4 variablesNEW Product!
  • MODBUS standard
  • Optional 2 relay and 4 analog outputs, 2 digital I/O
  • Optional 2 relay, 6 digital I/O
  • Optional data logging
  • Alarm contact triggered on any setpoint
  • Includes measurement & configuration software
  • 100-230 VAC or 24-230 VDC powered
A Plus Brochure
CE logo A Plus Instructions
A Plus Modbus
A Plus Modbus/TCP
CB Manager Software
Multi-Function Energy Transducers
Sineax CAM Multifunction Energy Transducer
Input: 0-1A, 0-5 A or
Two 4-20 mA
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Digital I/O
Output: RS-485 MODBUS interface
USB 2.0
Relay
Up to 4 analog
Digital I/O
CAM
Top of page
  • True RMS
  • Simultaneous measurement of all 3 phases
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, LF, f, THD, TDD, VAR
  • USB programming interface
  • 85-265 VAC/ 110-265 VDC powered
  • Optional 17-90 VDC powered
CE logo CAM Specifications
CAM Instructions
CAM Software
MODBUS Instructions
Sineax A200 Multifunction Display for DME Power Transducers
Input: Serial data from DME4 series Output: 3 digital displays A200 Top of page
  • 1/4 DIN (96 x 96 mm) display for DME4 transducers
  • Triple LED display 14 mm digit height
  • Selectable display parameters
  • 20-265 VAC/VDC powered
CE logo
A200 Specifications
A200 Instructions
Sineax DME 400 Energy Transducer with LONWORKS Interface
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: LONWORKS with LONTalk protocol DME 400
Top of page
lonworks logo
  • LONWORKS interface
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data logging function
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
CE logoCSA logo DME400 Specifications
DME400 Instructions
DME Software
LONWORKS Instructions
Sineax DME 401 Energy Transducer with MODBUS Interface
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: RS-485 MODBUS interface DME 401
Top of page
  • RS-485 MODBUS interface
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data logging function
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
CE logoCSA logo DME 401 Specifications
DME 401 Instructions
DME Software
MODBUS Instructions
MODBUS Basics
Sineax DME 440 Energy Transducer w. MODBUS & 4 Analog Outputs
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: RS-485 MODBUS interface
4 analog outputs:
0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
DME 440
Top of page
  • RS-485 MODBUS interface
  • 4 analog outputs
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data logging function
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
CE logoCSA logo DME 440 Specifications
DME 440 Instructions
DME Software
Sineax DME 406 Energy Transducer with PROFIBUS Interface
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: PROFIBUS DP DME 406

Top of page
profibus logo
  • PROFIBUS DP interface
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data logging function
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
CE logoCSA logo DME 406 Specifications
DME 406 Instructions
DME Software
PROFIBUS Instructions
PROFIBUS GSD File
Sineax DME 424 & DME 442 Energy Transducers w. Analog and Pulse Outputs
Input: 0-0.8 A to 0-1.2 A or
0-4 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50/60 Hz
Output: 0-20 mA, 4-20 mA
0-1 V to 0-10 V, 2-10 V
Open collector pulse
DME 442

Top of page
  • DME 424 with 2 analog and 4 digital pulse outputs
  • DME 442 with 4 analog and 2 digital pulse outputs
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin j, LF, PF, QF, f
  • Data logging function
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
CE logoCSA logo DME 424/DME 442 Specifications
DME 424/DME 442 Instructions
DME Software
Power & Current Transducers
Sineax M 561 Power & Current Transducer
Input: 0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz
Output: One analog output
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V
M 561
Top of page
  • 1 analog output
  • Measures any One: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
CE logoCAS logo M 561 Specifications
M 561 Instructions
A200 Plus Software
Sineax M 562 Power & Current Transducer
Input: 0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz
Output: 2 analog outputs
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V
M562
Top of page
  • 2 analog outputs
  • Measures any two: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
CE logo CSA logo M 562 Specifications
M 562 Instructions
A200 Plus Software
Sineax M 563 Power & Current Transducer
Input: 0-1 A to 0-6 A
57-400 V phase-to-neutral
100-693 V phase-to-phase
50 or 60 Hz
Output: 3 analog outputs
0-20 mA, 4-20 mA
0-1 V to 0-10 V
2-10 V
M 563
Top of page
  • 3 analog outputs
  • Measures any Three: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
CE logoCSA logo M 563 Specifications
M563 Instructions
A200 Plus Software

Phone:  800-942-0315 or 847-918-3510   Fax:  800-949-7502 or 847-968-4891