API-Camille Bauer USA Signal Conditioners, Isolators, Process Transmitters Electrical Power Monitors and Transducers, Rotary Position Sensors |
Sensors to Solutions 800-942-0315 |
||
![]() API-Camille Bauer |
![]() API Signal Conditoners |
![]() APCS Signal Conditoners |
![]() Cecomp Digital Pressure Gauges |
![]() RheinTacho Speed Monitors and Sensors |
|
Request a Quote or Ask a Question Applications Sineax Power Monitors Sineax Power Transducers Sineax Signal Conditioners, Isolators, & Converters Sineax Temperature Transmitters Kinax Rotary Position Transducers Doing Business With Us About Us FAQ Camille Bauer, Switzerland |
|
|
| Power Transducers | ||
|---|---|---|
| Sineax P 530 Active Power & Q 531 Reactive Power Transducers | ||
|
Input: 0-0.8 A to 0-1.2 A or, 0-4 A to 0-6 A, 100-690 V, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
Instructions, Single Phase Models Instructions, 3-Phase Models CE Declaration, All Versions CSA Certificate GL Certificate for Shipboard Use, 3-Phase Version |
![]() |
|
| Current Transducers | ||
| Sineax I 538 AC Current Transducer | ||
| Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 50/60 Hz Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
Instructions CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Sineax I 542 AC Current Transmitter | ||
|
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
Instructions CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Sineax I 552 True RMS AC Current Transducer | ||
|
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT , 50/60 or 400 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
Instructions CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Voltage Transducers | ||
| Sineax U 539 AC Voltage Transducer | ||
|
Input: 0-50 V to 0-600 V, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
Instructions CE Declaration U539 CE Declaration U539-2 Two Wire Versions CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Sineax U 543 AC Voltage Transducer | ||
|
Input: 0-20 V to 0-600 V, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
Instructions CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Sineax U 553 True RMS AC Voltage Transducer | ||
|
Input: 0-20 V to 0-690 V, 50/60 or 400 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V]
Instructions CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Sineax U 554 True RMS AC Voltage Transducer | ||
|
Input: 0-20 V to 0-690 V, 50/60 or 400 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
Instructions CE Declaration |
![]() |
|
| Frequency Transducers | ||
| Sineax F 534 Frequency Transducer | ||
|
Input: 10 V to 690 V, 10 to 1500 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, to ±10 V
Instructions CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Sineax F 535 Frequency Difference Transducer | ||
| Input: 10 V to 690 V, 10 to 1500 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, to ±10 V
Instructions CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Phase Angle (Power Factor) Transducers | ||
| Sineax G 536 Phase Angle Transducer | ||
|
Input: 1 or 5 A from CT, 10 V to 690 V, 16 to 400 Hz, 0.5 cap. 1.ind. 0.5 cos Φ
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
Instructions CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Sineax G 537 Phase Angle Difference Transducer | ||
|
Input: 10 V to 690 V, 50 or 60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
CE Declaration CSA Certificate GL Certificate for Shipboard Use |
![]() |
|
| Power & Current Transducers | ||
| Sineax M 561 Power & Current Transducer | ||
|
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz One Analog Output: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
M 561/562/563 Series Instructions M 561 CE Declaration M 561 CSA Certificate Software for M561/562/563 series |
![]() |
|
| Sineax M 562 Power & Current Transducer | ||
|
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz Two Analog Outputs: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
M 561/562/563 Series Instructions M 562 CE Declaration M 562 CSA Certificate Software for M561/562/563 series |
![]() |
|
| Sineax M 563 Power & Current Transducer | ||
|
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz Three Analog Outputs: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
M 561/562/563 Series Instructions M 563 CE Declaration M 563 CSA Certificate Software for M561/562/563 series |
![]() |
|
| Multi-Function Power Meters | ||
| Sineax CAM Multifunction Energy Transducer | ||
|
Input: 0-1A, 0-5 A from CT or Two 4-20 mA, 57-400 V phase-to-neutral, 100-693 V phase-to-phase,
50/60 Hz, Digital I/O Output/Communications: RS-485 MODBUS, Relay, Up to 4 analog, Digital I/O, USB 2.0 programming interface
CAM with Rogowski Sensors CAM Data Sheet CAM Instructions CAM Instruction Supplement for Graphic Display CAM Safety Instructions CE Declaration CAM Installation of IEC 61850 option CAM Instructions for IEC 61850 option CAM IEC 61850 Certificate CB Manager Software CB Data Analylysis Software CAM ICD Files MODBUS Basics MODBUS Instructions MODBUS/TCP Instructions |
![]() IEC 61850 |
|
| Sineax A200 Multifunction Display for DME Power Transducers | ||
| Input: Serial data from DME4 series
Output: 3 digital displays
Instructions CE Declaration |
|
|
| Sineax DME 406 Energy Transducer with PROFIBUS Interface | ||
|
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz
Output: PROFIBUS DP interface
DME 406 Instructions DME 406 CE Declaration DME Series CSA Certificate PROFIBUS Certificate PROFIBUS Instructions DME Software PROFIBUS GSD File |
|
|
| Sineax DME 424 & DME 442 Energy Transducers w. Analog and Pulse Outputs | ||
| Input: 0-0.8 A to 0-1.2 A o 0-4 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz
Output: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V, Open collector pulse
DME 424/DME 442 Instructions DME Series CE Declaration DME Series CSA Certificate DME Software |
|
|
| Phone: 800-942-0315 or 847-918-3510 | Home Page | Fax: 800-949-7502 or 847-968-4891 |