API
api-cb logo
API-Camille Bauer Division of
Absolute Process Instruments, Inc.

Signal Conditioners, Signal Isolators, Process Transmitters
Electrical Power Monitors, Electrical Power Transducers,
Rotary Position Sensors
apicb API CecompGauges APCS products Rheintacho products
power brochure Click on link to go to:

Power Transducers
Multi-Function Meters
Multi-Function Transducers
Power & CurrentTransducers

Heavy Current Engineering Product Brochure pdf
Multi-Function Power Meters
Sineax A210 & A220 Multifunction Power Meters
Input: Single or 3-phase, 0-1 A to 0-6 A from CT, 290 V phase-to-neutral, 500 V phase-to-phase, 50/60 Hz

Output: Digital pulse, relay. See EMMOD modules below for additional I/O capabilities
  • A210 1/4 DIN size or A220 full-size DIN
  • 19 types of measurements including
  • P, Q, S, I~, U~ (rms), cos φ, (PF, 4 quadrants), f, Pint, Qint, Sint
  • 3 programmable displays
  • Open collector alarm relay and pulse outputs
  • Data logging, RS232, and MODBUS with EMMOD 201 option
  • Two analog outputs with EMMOD 202 option
  • Ethernet interface with EMMOD 203 option
  • PROFIBUS interface with EMMOD 204 option
  • Hi/Lo electrical rates
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
A210/A220/A230/A230s Series Brochure
A210/A220 Data Sheet
A210/A220 Instructions
A210 CE Declaration
A220 CE Declaration
A210 and A220

UL approved    CE logo
Sineax A230 & A230s Multifunction Power Meter w. System Load & Harmonics
Input: Single or 3-phase, 0-1 A to 0-6 A from CT, 290 V phase-to-neutral, 500 V phase-to-phase, 50/60 Hz

Output: Digital pulse, relay. See EMMOD modules below for additional I/O capabilities
  • A230 full-size DIN or A230s 1/4 DIN
  • 19 types of measurements including
  • P, Q, S, I~, U~ (rms), cos φ (PF, 4 quadrants), f, Pint, Qint, Sint, THD, harmonics, UNE, unbU
  • Three 4-digit programmable displays
  • Open collector alarm relay and pulse outputs
  • Data logging, RS-232, and MODBUS with optional EMMOD 201
  • Two analog outputs with EMMOD 202 option
  • Ethernet interface with EMMOD 203 option
  • PROFIBUS interface with EMMOD 204 option
  • Hi/Lo electrical rates
  • Comprehensive mean and max./min. value functions with trend
  • System analysis functions (THD, harmonics, asymmetry)
  • Higher accuracy
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
A210/A220/A230/A230s Series Brochure
A230/A230s Data Sheet
A230/A230s Instructions
A230 CE Declaration
A230s CE Declaration
A230 and A230s

UL approved    CE logo

Top of page
EMMOD modules for A210, A220, A230, A230s Multifunction Power Meters
Input: Data connection from rear of power meter

Output/Communications
EMMOD201 Switchable RS232/RS485 (Modbus) interface, data logger, digital input
EMMOD202 2 Analog Outputs
EMMOD203 Ethernet interface (Modbus/TCP, HTTP), data logger with timestamp, 2 digital inputs
EMMOD204 Profibus DP interface
EMMOD205 LON interface, digital I/O
EMMOD206 M-Bus interface, digital input

The EMMOD modules extend the functionality of the A series power monitoring devices. Select the module with the bus interface, data logger, digital I/O or analog output features required.

A200Plus Software for EMMOD modules

EMMOD201 RS232/RS485/Datalogging Instructions
EMMOD201 MODBUS Setup Instructions
MODBUS Basics
EMMOD201 CE Declaration

EMMOD202 Analog Output Module Instructions
EMMOD202 CE Declaration

EMMOD203 Ethernet Installation Instructions
EMMOD203 Ethernet Interface Instructions
EMMOD203 CE Declaration

EMMOD204 PROFIBUS Instructions
EMMOD204 PROFIBUS GSD File
EMMOD204 CE Declaration

EMMOD205 LON Interface Instructions
EMMOD205 CE Declaration

EMMOD206 M-Bus Interface
EMMOD206 CE Declaration
emmod

UL approved  CE logo

Modbus

profibus logo

M-bus

LON
Sineax A-Plus True RMS Multifunction Power Meter with Power Quality Analysis
Input: Single or 3-phase, 0-1A to 0-6 A from CT, 400 V phase-to-neutral, 690 V phase-to-phase, 50/60 Hz, 1 digital input

Output: Programmable digital pulse, relay, Modbus
  • Power quality analysis
  • Display 4 variablesNEW Product!
  • MODBUS standard
  • Optional 2 relay and 4 analog outputs, 2 digital I/O
  • Optional 2 relay, 6 digital I/O
  • Optional data logging
  • Alarm contact triggered on any setpoint
  • Includes measurement & configuration software
  • 100-230 VAC or 24-230 VDC powered
A Plus Brochure
A Plus Instructions
A Plus Safety Instructions
A Plus CE Declaration
A Plus PROFIBUS Certificate

CB Manager Software
CB Data Analysis Software
A Plus Modbus
A Plus Modbus/TCP
A Plus PROFIBUS GSD Files
A Plus Software
A Plus

CE logo

Modbus

Profibus

Top of page
Multi-Function Energy Transducers
Sineax CAM Multifunction Energy Transducer
Input: 0-1A, 0-5 A from CT or Two 4-20 mA, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz, Digital I/O

Output/Communications: RS-485 MODBUS, Relay, Up to 4 analog, Digital I/O, USB 2.0 programming interface
  • True RMS
  • Simultaneous measurement of all 3 phases
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, LF, f, THD, TDD, VAR
  • 85-265 VAC/ 110-265 VDC powered
  • Optional 17-90 VDC powered
CAM Brochure
CAM with Rogowski Sensors
CAM Data Sheet
CAM Instructions
CAM Instruction Supplement for Graphic Display
CAM Safety Instructions
CE Declaration

CAM Installation of IEC 61850 option
CAM Instructions for IEC 61850 option
CAM IEC 61850 Certificate


CB Manager Software
CB Data Analylysis Software
CAM ICD Files
MODBUS Basics
MODBUS Instructions
MODBUS/TCP Instructions
CAM
CAM with display

Modbus

IEC 61850

  CE logo
Top of page
Sineax A200 Multifunction Display for DME Power Transducers
Input: Serial data from DME4 series

Output: 3 digital displays
  • 1/4 DIN (96 x 96 mm) display for DME4 transducers
  • Triple LED display 14 mm digit height
  • Selectable display parameters
  • 20-265 VAC/VDC powered
Data Sheet
Instructions
CE Declaration
A200

CE logo
Top of page
Sineax DME 406 Energy Transducer with PROFIBUS Interface
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz

Output: PROFIBUS DP interface
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • Data logging function
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
DME 406 Data Sheet
DME 406 Instructions
DME 406 CE Declaration
DME Series CSA Certificate

PROFIBUS Certificate PROFIBUS Instructions
DME Software
PROFIBUS GSD File
DME 406

profibus logo CE logo  CSA logo Top of page
Sineax DME 424 & DME 442 Energy Transducers w. Analog and Pulse Outputs
Input: 0-0.8 A to 0-1.2 A o 0-4 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz

Output: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V, Open collector pulse
  • DME 424 with 2 analog and 4 digital pulse outputs
  • DME 442 with 4 analog and 2 digital pulse outputs
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin j, LF, PF, QF, f
  • Data logging function
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
DME 424/DME 442 Data Sheet
DME 424/DME 442 Instructions
DME Series CE Declaration
DME Series CSA Certificate

DME Software
DME 442

CE logo  CSA logo
Top of page
Power & Current Transducers
Sineax M 561 Power & Current Transducer
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz

One Analog Output: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
  • 1 analog output
  • Measures any One: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
M 561/562/563 Series Data Sheet
M 561/562/563 Series Instructions
M 561 CE Declaration
M 561 CSA Certificate

Software for M561/562/563 series
M 561

CE logo  CSA logo
Top of page
Sineax M 562 Power & Current Transducer
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz

Two Analog Outputs: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
  • 2 analog outputs
  • Measures any two: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
M 561/562/563 Series Data Sheet
M 561/562/563 Series Instructions
M 562 CE Declaration
M 562 CSA Certificate

Software for M561/562/563 series
M562

CE logo  CSA logo
Top of page
Sineax M 563 Power & Current Transducer
Input: 0-1 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50 or 60 Hz

Three Analog Outputs: 0-20 mA, 4-20 mA, 0-1 V to 0-10 V, 2-10 V
  • 3 analog outputs
  • Measures any Three: P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • RS 232 PC programming interface
  • 24-60 VAC/VDC or 85-230 VAC/VDC powered
M 561/562/563 Series Data Sheet
M 561/562/563 Series Instructions
M 563 CE Declaration
M 563 CSA Certificate

Software for M561/562/563 series
M 563

CE logo  CSA logo
Top of page

Phone:  800-942-0315 or 847-918-3510   Fax:  800-949-7502 or 847-968-4891
apicb.com Home Page
Copyright © 1999-2012 Absolute Process Instruments, Inc.